Tool
TAR validation calculator: elusion sample size and recall range
Enter the size of your null set to see how many documents to sample for an elusion test. After you review the sample, enter what you found to see the elusion rate, the estimated number of missed documents and the recall range.
Step 1: size the sample
Sample 2,345 documents at random from the null set.
At this size, a result is accurate to within ±2% at the chosen confidence level if the true rate is near the expected rate.
Step 2: read the result
Enter the number of responsive documents found in the sample to see the elusion rate, the estimated missed documents and the recall range. The null set size and confidence level carry over from step 1.
How this is calculated
- z is 1.645 at 90% confidence, 1.96 at 95% and 2.576 at 99%.
- Sample size: n0 = z² × p × (1 − p) ÷ E², then n = n0 ÷ (1 + (n0 − 1) ÷ N), rounded up and never more than N. p is the expected elusion rate, E the margin of error and N the null set size.
- Elusion rate: responsive documents found in the sample ÷ sample size.
- The range is a Wilson score interval for that rate at the chosen confidence level. When no responsive documents are found in the sample, the low end is shown as 0.
- Estimated missed documents: N × the elusion rate, with the range from N × the low and high ends.
- Estimated recall: R ÷ (R + estimated missed documents), where R is the responsive documents the review found. The low end of the recall range uses the high end of the missed range, and the reverse.
What the numbers mean
- The elusion rate is the share of the null set that is responsive, estimated from a random sample. The range shows how far the true rate could reasonably be from the sample’s rate.
- Recall is the share of all responsive documents that the review found. It is estimated here from the documents the review found and the documents the sample suggests were missed.
- Read the low end of the recall range, not only the middle. A small sample gives a wide range.
Limits
- This estimate treats every document the review marked responsive as responsive. If reviewers over-marked, real recall is lower than shown.
- An elusion sample alone can overstate recall. Many protocols pair it with a control set or a sample across the whole collection. Use the method your ESI protocol or the court’s order requires.
- The sample must be random and drawn from the whole null set.
- This page is general information, not legal advice. It does not say what recall a court will accept in your matter.
Read next
Sources
Questions about validating a review in Legal Lens? Ask us.